ECUsim™ 2000 User Guide 15
21
Distance Traveled
While MIL is
Activated
fixed
03E8
1000 km
2F
Fuel Level Input
fixed
80
50.2%
33
Barometric
Pressure
fixed
64
100 kPa
40
Supported PIDs
41-5F
fixed
44000000
42
Control Module
Voltage
fixed
2EE0
12 V
46
Ambient Air
Temperature
fixed
3C
20°C
7.1.1.1 PID 01 Monitors
Continuous Monitors
Monitor
Supported
Ready
Misfire
Yes
Yes
Fuel System
Yes
Yes
Comprehensive Component (CCM)
Yes
Yes
Compression Ignition Supported
No
Non-continuous Monitors
Monitor
Supported
Ready
Catalyst
Yes
Yes
Heated Catalyst
Yes
Yes
Evaporative System
Yes
Yes
Secondary Air System
Yes
Yes
A/C System Refrigerant
No
Oxygen Sensor
Yes
Yes
Oxygen Sensor Heater
Yes
Yes
EGR System
Yes
No